MCL-GH01 Full Auto HbA1c Diabetes Test Equipment
Full Auto HbA1c Diabetes Test Equipment
Model: MCL-GH01
Specification of the Full Auto HbA1c Diabetes Test Equipment :
Testing Method | Low pressure ion exchange liquid chromatography |
Testing Item | Glycated hemoglobin HbA1c |
Testing Scope | 3%-18% |
Testing Parameters | Precision(CV)≤3%, Accuracy(V) ≤1.50% |
Testing Time | 4 minutes(reporting), Full-processing 6 minutes(including cleaning column and recovery time) |
Sample Type | Venous blood(EDTA anticoagulation), Peripheral finger blood |
Sample Volume | 5ul Whole blood for each sample |
Functional Parameters | |
Photometer | 415nm LED Integral flow colorimeter |
Sampling mode | Fully-auto 20 position sample turntable |
Testing mode | Auto test for batch, single test for emergency |
Calibration | Optional selection of 2 points or 4 points calibration, optional selection of manual or automation, Equipped with 2 groups of high and low level calibrators |
Thermostatic control | Column and reagent thermostatic control: 25 ±0.5°C |
Reagent matching | One piece of column and reagent consumable/300 pieces of testing samples |
Reagent allocation | Each standard package inclues A, B, C, D eluent, calibrator, hemolytic agent, pump tubing |
Output Parameters | |
Display | 320×240 LC Graphic display, displaying real-time testing curve |
Printer | 58nm Thermal printer, printing testing curve and report |
Report Output | IFCC concentration value, NGSP area percentage, ADAG average glucose |
Data storage | 1000test report(including testing curve) |
Communication interface | RS232 communication interface, connecting to HIS/LIS system |
Working Parameters | |
Power Supply | AC220V±22V, 50HZ, 65VA |
Size | 408*390*230mm |
Weight | 8KG |
Working Environment | Temperature 12-30°C, Relative humidity ≤85% |